Kaleido Coffee Roasters (M1, M2, M6 & M10)

All Kaleido Coffee Roasters must be connected to the correct electrical supply as specified below to ensure safe operation, stable performance, and equipment longevity.

Failure to follow these requirements may result in equipment damage or safety hazards.

Power Requirements

ModelPower / WattageElectrical Requirement
M11000W (120V)15A Dedicated 120V Circuit
M21600W (120V)15A Dedicated 120V Circuit
M62200W (120V/240)20A Dedicated 120V Circuit or
240V with L6-20 Receptacle
M102200W (120V) / 2600W (240V)20A Dedicated 120V Circuit or 240V with L6-20 Receptacle

The wattage listed above represents the maximum power rating of each Kaleido roaster model. Ensure your electrical setup meets the recommended circuit requirements before operation.

M1 & M2 Models

Electrical Specifications

  • Voltage: 110–120V AC
  • Plug Type: NEMA 5-15P (standard North American 3-prong plug)
  • Outlet Type: NEMA 5-15R
  • Circuit Requirement: Standard 15A circuit (no dedicated circuit required under normal use)
  • Frequency: 60Hz

Installation Notes

M1 and M2 models are designed for plug-and-operate use.

For best performance:

  • Use a stable grounded outlet
  • Avoid sharing the circuit with high-draw appliances (e.g., heaters, kettles, microwaves)
  • Do not use extension cords

M6 & M10 Models

110V Operation

  • Voltage: 110–120V AC
  • Outlet Type: 20A rated receptacle (NEMA 5-20R or equivalent)
  • Circuit Breaker: Minimum 2-pole (2P), 20A
  • Circuit Type: Dedicated, grounded circuit with correctly sized wiring (no shared loads)
  • Frequency: 60Hz

220V Operation

  • Voltage: 220–240V AC
  • Factory-Installed Plug: NEMA L6-20P (locking plug)
  • Required Outlet: NEMA L6-20R (20A, 250V locking receptacle)
  • Circuit Breaker: Minimum 2-pole (2P), 20A
  • Circuit Type: Dedicated, grounded circuit with correctly sized wiring (no shared loads)
  • Frequency: 60Hz

Installation Requirements (M6 & M10)

A licensed electrician should verify installation before operation.

Proper installation must ensure:

  • Dedicated electrical circuit
  • Correct voltage compatibility
  • Proper grounding
  • Correct breaker sizing
  • Wiring rated for continuous load

Improper installation may result in:

  • Electrical overload
  • Equipment malfunction
  • Reduced roasting performance
  • Safety hazards

General Safety Information

All models must be operated within their specified electrical limits.

Kaleido Roasters Canada is not responsible for damage, malfunction, or safety issues resulting from:

  • Incorrect electrical installation
  • Use outside specified voltage range
  • Non-compliant wiring or breakers
  • Improper adapters or power configurations

Best Practice Guidelines

  • Verify outlet compatibility before first use
  • Use dedicated circuits for M6 and M10 models
  • Do not use extension cords for high-power equipment
  • Ensure stable voltage supply at all times
  • Consult a licensed electrician when uncertain